Government Affair
Project committee meeting (2/2024) development of SIRIM Industry Standard
Venue: Bilik ISO, Tingkat 3, Bangunan 3, SIRIM STS Sdn Bhd (Shah Alam)
Date: 26 Feb 2024
Time: 9:30am - 1:00pm
Download: More Information
| Chapter Chair: | GAC |
| Event: | Project committee meeting (2/2024) development of SIRIM Industry Standard on Healthy Purification of Refrigerating Appliances for Household and Similar Use |
| Organization: | SIRIM STS Sdn Bhd |
| Government Agency | SIRIM STS Sdn Bhd |
| Organised By: | SIRIM STS Sdn Bhd |
| Date: | 26th February 2024 |
| Time: | 9.30am to 1.00pm |
| Place: | Bilik ISO, Tingkat 3, Bangunan 3, SIRIM STS Sdn Bhd (Shah Alam) |
| Report By: | Dr Chin Wai Meng |
| MASHRAE Rep: | Dr Chin Wai Meng |
| Air Conditioning industries | Midea (China), Daikin, MACRA |
| Other participants: | SIRIM, Jabatan Kimia Malaysia, Institut Kimia Malaysia, Universiti Malaya, Universiti Teknologi Mara |
| Report: | |
| The Chairman, En Harun bin Ahmad, welcomed the members of the project committee. | |
| 1. Since there were quite a few new members joining the meeting, the Secretariat presented again the background | |
| of the project. | |
| 2. The Terms and Definitions used in the draft standard were reviewed and improved for clarity. | |
| 3. The committee spent a considerable amount of time to discuss and review the scope of the SIRIM Industry | |
| Standard. It was agreed that the standard is to establish test methods to evaluate the healthy purification of | |
| household refrigerating appliances, and similar use. | |
| 4. The Chairman clarified that this standard should be applied to the finished product (refrigerator) where, if | |
| necessary, samples of materials or components can be cut from it for the tests mentioned in the Annex. | |
| 5. Clause 4 was changed to "General Requirements". Table 1 was removed. | |
| 6. The committee reviewed and clarified the requirements in "General Test Conditions" of Clause 5.1 | |
| 7. Discussion was started on Clause 5 "Test Method" - Deodorization rate, leading to Annex A. | |
| Question was raised if SIRIM QAS has the necessary equipment and capability to conduct the test. | |
| However, due to time consideration, the discussion will be continued in the next meeting. | |
| Next meeting (3/24): 5th March, 2024, 9.30am. This will be a hybrid meeting. | |
| Members from Midea (China) will join via online. |